Ask a Question
Coherent
PLECTER

Industrial picosecond laser consisting of compact, long-life 80 MHz oscillator and power amplifier, ideally suited for pumping in non-linear optics applications and Raman Spectroscopy.

The PLECTER industrial picosecond laser is a 80 MHz quasi-CW laser offering a high level of power and beam pointing stability. The laser offers more than 10W of TEM00 power at 1064 nm or 5W at 532 nm; partial conversion to SHG can be specified.

The PLECTER has excellent beam pointing stability, waist-location stability, and waist-size stability. These features make the PLECTER a cost-effective platform for various industrial applications in medical equipment, measurement devices and display technology.

Applications
Application
Process

Scientific
Medical Imaging
OPCPA Pumping
Features & Benefits

  • Custom Configurations: 10W at 1064 nm; 5W at 532 nm
  • 80 MHz oscillator and power amplifier
  • Excellent pulse energy and beam pointing stability
  • High beam quality M2 < 1.2
  • Field replaceable pump diodes in laser head
  • Actively stabilized SHG output power
PLECTER 1064
PLECTER 532
Wavelength
1064 nm
532 nm
Average Power (W)
10
5
Repetition Rate (MHz)
80
Spatial Mode
TEM00 (M² < 1.2)
Pulse Duration (ps)
8
7
Pulse-to-Pulse Energy Stability (% rms)
<0.5
<1
Average Power Stability over 8 hours(% rms)
<0.5
<1
Polarization Ratio
>>100:1
Beam Divergence, Full Angle (mrad)
<2
Beam Circularity (%)
>85
Beam Pointing Stability (µrad/°C)
<50
Beam Diameter (at bezel)(mm)
1.5±0.2
1.2±0.2
Bore-Sight Accuracy
±0.5 mm and <5 mrad
Umbilical Length (m)
2.8
Electric Supply, 19” Rack
10 to 230VAC, 50 to 60 Hz, 400W
Laser Head Dimensions (W x L x H; weight)
208 x 657 x 108 mm; 20 kg
Warm-Up Time (minutes)
<45 from cold start

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions